Sökning: "Unbalanced magnetic pull"
Visar resultat 1 - 5 av 6 avhandlingar innehållade orden Unbalanced magnetic pull.
1. Analysis and control of magnetic forces in synchronous machines
Sammanfattning : In a synchronous machine, radial, tangential, and axial forces are generated. In this thesis, three different technologies to control them are proposed. The first one, involves the utilization of the radial forces that arise between the rotor and the stator. LÄS MER
2. Measurement and modelling of unbalanced magnetic pull in hydropower generators
Sammanfattning : Hydropower research is often perceived to be an old and exhausted field of study but with ageing equipment and the need for more intermittent operation caused by an increased share of other renewable energy sources new challenges lie ahead.The main focus of this dissertation are the electromagnetic forces resulting from nonuniform air gap flux, whether it be caused by rotor eccentricity or a faulty field winding. LÄS MER
3. Improving the functionality of synchronous machines using power electronics
Sammanfattning : With the advent of modern power electronics there is reason to explore what can be achieved when it is applied to a mature technology like synchronous machines. In this text several concepts will be presented on how it is possible to control forces and how to get better performance out of synchronous machines by using power electronics. LÄS MER
4. On the dynamics of an hydropower generator subjected to unbalanced magnetic pull : characterisation and analysis
Sammanfattning : Eccentricity leading to unbalanced magnetic pull (UMP) in rotating electrical machines is a significant concern in industry. The UMP arises due to magnetic flux crossing the air-gap between the rotor and stator, and can be more intense than the useful peripheral force that the machine develops. LÄS MER
5. Contributions to the electromechanics of unbalanced magnetic pull in a synchronous hydropower generator
Sammanfattning : Misalignment between the rotor geometrical axis and the geometrical stator axis in a hydropower generator is usually present at standstill and when the machine is under operation. Now, rotor-stator eccentricity in a rotating electrical machine is a harbinger to abnormal operating conditions of the machine. LÄS MER