Sökning: "water treeing"

Visar resultat 1 - 5 av 6 avhandlingar innehållade orden water treeing.

  1. 1. The Effect of Crosslinking on Morphology and Water Treeing in LDPE

    Författare :Susanne Nilsson; Chalmers tekniska högskola; []
    Nyckelord :NATURVETENSKAP; NATURAL SCIENCES; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; water treeing; peroxide; network structure; crosslinking; morphology; LDPE;

    Sammanfattning : Crosslinked polyethylene (XLPE) is used as underground cable insulation due to its outstanding electrical properties and high temperature dimension stability. XLPE is made by peroxide initiated crosslinking of low density polyethylene. In recent years, polyethylene with unsaturations, i.e. LÄS MER

  2. 2. The Effect of Crosslinking on Morphology and Electrical Properties in LDPE Intended for Power Cables

    Författare :Susanne Nilsson; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; LDPE; morphology; electrical treeing; peroxide; crosslinking; XLPE; water treeing;

    Sammanfattning : Crosslinked polyethylene (XLPE) is used as underground cable insulation due to its outstanding electrical properties and high temperature dimension stability. XLPE is often made by peroxide initiated crosslinking of low density polyethylene (LDPE). The introduction of unsaturations, i.e. LÄS MER

  3. 3. Techniques for Localization of Insulation Degradation along Medium-Voltage Power Cables

    Författare :Ruslan Papazyan; Roland Eriksson; Fred Steennis; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Electrical power technology; Attenuation measurement; cross-linked polyethylene insulation; discontinuities; localization; mass-impregnated insulation; numerical analysis; parameter estimation; power cable metallic screen; scattering parameters; time domain reflectometry; velocity measurements; water treeing; Elkraftteknik; Electric power engineering; Elkraftteknik;

    Sammanfattning : Time Domain Reflectometry (TDR) has been used for localization of transmission line discontinuities in diverse applications. Various challenges have to be addressed when applying TDR for localization of insulation degradation in power cables. LÄS MER

  4. 4. Dielectric properties of poly(ethyelene-co-butyl acrylate) filled with Alumina nanoparticles

    Författare :Nadejda Jäverberg; Hans Edin; Eva Mårtensson; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; nanocomposites; poly ethylene-co-butyl acrylate ; EBA; alumina; dielectric permittivity; absorbed water; humidity; temperature; dielectric spectroscopy; partial discharge; electrical treeing; Electrical engineering; Elektroteknik;

    Sammanfattning : In this work dielectric properties of the poly(ethylene-co-butyl acrylate)filled with alumina nanoparticles are evaluated. These nanocomposite materialswere manufactured at the department of Fibre and Polymer Technology,KTH.This study is limited to the properties of general importance for the AC applications. LÄS MER

  5. 5. Development and application of high voltage dielectric spectroscopy for diagnosis of medium voltage XLPE cables

    Författare :Peter Werelius; KTH; []
    Nyckelord :dielectric spectroscopy; high voltage; variable frequency; diagnostics; non-disgnostics;

    Sammanfattning : When polymer power cables were introduced into mediumvoltage applications in the late 1960s, the degradationphenomenon later referred to aswater treeingwas still unknown. However, this changedwithin a relatively short space of time. LÄS MER