  1. 21. Computer Modelling of Electrophysical Phenomena in High Voltage Insulation

    Författare :Yuriy Serdyuk; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; dielectric properties; discharge plasma; composite material; computer model; numerical simulations; electrical discharge;

    Sammanfattning : Different kinds of dielectrics are used for high voltage insulation. In most of the cases, they are combined into complex insulating systems forming macro- and micro-scale composite structures. LÄS MER

  2. 22. Biofilms on silicone rubber for outdoor high voltage insulation

    Författare :Stina Wallström; Sigbritt Karlsson; Paul Gatenholm; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Chemical engineering; polymer technology; Kemiteknik; Chemical engineering; Kemiteknik;

    Sammanfattning : Silicone rubber high voltage insulators are sometimes colonised by microorganisms which form a biofilm on the surface of the infected unit. In this work insulators exposed to the outdoor environment in Sweden, Sri Lanka and Tanzania respectively have been studied. LÄS MER

  3. 23. Electrical Charges on Polymeric Insulator Surfaces and their Impact on Withstand Performance

    Författare :Sarath Kumara; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; impulse corona; Surface charge; impulse flashover voltage; corona charging; streamer criterion; surface potential decay; charge relaxation;

    Sammanfattning : Use of polymeric materials for high voltage outdoor insulation systems is increasing continuously. Insulating polymers gradually replace traditional materials like porcelain and glass and become dominant at ultra high voltages, e.g., in 1000 kV ac and 800 kV dc overhead power transmissions, which are presently being developed. LÄS MER

  4. 24. Electric Charges on Insulator Surfaces and their Influence on Insulator Performance

    Författare :Hans Sjöstedt; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; EPDM; silicone rubber; material properties; surface potential measurements; outdoor insulation materials;

    Sammanfattning : AbstractPolymeric materials used in high voltage insulation systems are subjected to electric fields which can be strong enough to initiate electrical discharges in the surrounding gas environment. Generated electrical charges may be deposited on polymer surfaces and alter electric field distributions, thus affecting insulation performance and their corresponding breakdown characteristics. LÄS MER

  5. 25. The Effect of Crosslinking on Morphology and Electrical Properties in LDPE Intended for Power Cables

    Författare :Susanne Nilsson; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; LDPE; morphology; electrical treeing; peroxide; crosslinking; XLPE; water treeing;

    Sammanfattning : Crosslinked polyethylene (XLPE) is used as underground cable insulation due to its outstanding electrical properties and high temperature dimension stability. XLPE is often made by peroxide initiated crosslinking of low density polyethylene (LDPE). The introduction of unsaturations, i.e. LÄS MER