Sökning: "spin echo"

Visar resultat 1 - 5 av 38 avhandlingar innehållade orden spin echo.

  1. 1. Nuclear Magnetic Resonance for Diffusion Imaging Development and evaluation of spin-echo-based pulse sequences for in vivo studies of water self-diffusion

    Författare :Sara Brockstedt; Lund Medicinsk strålningsfysik; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; perfusion fraction; electrocardiographic triggering; segmented EPI SEPI ; echo-planar imaging EPI ; fast spin-echo FSE ; spin-echo SE ; navigator echoes; phase corrections; diffusion; Magnetic resonance; MRI; ischaemic stroke; Medicine human and vertebrates ; Medicin människa och djur ;

    Sammanfattning : The interest in diffusion imaging with nuclear magnetic resonance techniques has increased during the last few years. The main reason is the possibility of early diagnosis of acute ischaemic stroke, at a time when conventional MR techniques and computerised tomography fail. LÄS MER

  2. 2. MRI evaluation and image processing in gel dosimetry. A study of selected MRI properties and image processing in 3D gel dosimetry

    Författare :Peter Magnusson; Malmö Medicinsk strålningsfysik; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; Klinisk fysiologi; medical instrumentation; tomography; radiology; Clinical physics; image registering; multi-slice; slice profile; ferrous sulphate; polyacrylamide; 3D volume acquisition; RF field; B1 field; relaxation time; T1; T2; spin-echo; multi-spin-echo; stochastic noise; nonuniformity; SNR; radiologi; tomografi; medicinsk instrumentering; Radiopharmaceutical technology; Radiofarmaceutisk teknik; Physics; Fysik;

    Sammanfattning : Gel dosimetry is a new dosimetry method applied in radiation therapy. Gel dosimeters consist of a radiation sensitive gel, which can integrate absorbed doses from several radiation sources or beams. The dose to the gel can be evaluated by magnetic resonance imaging (MRI), a procedure that is the focus of the present thesis. LÄS MER

  3. 3. Characterisation of powder cellulose, microcrystalline cellulose and porous cellulose beads : application of 13 C CP/MAS and spin echo NMR techniques

    Författare :Ragnar Ek; Uppsala universitet; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; PHARMACY; FARMACI;

    Sammanfattning : .... LÄS MER

  4. 4. Analysis of relaxation time measurements with spin-echo magnetic resonance imaging : A study of selected clinical protocols

    Författare :Annette Fransson; Stockholms universitet; []
    Nyckelord :;

    Sammanfattning : .... LÄS MER

  5. 5. Susceptibility effects in MRI and 1H MRS. The spurious echo artifact and susceptibility measurements

    Författare :Åsa Carlsson; Göteborgs universitet; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MRI; 1H MRS; susceptibility; spurious echo; artifact; artefact;

    Sammanfattning : When performing magnetic resonance (MR) experiments, a strong homogeneous magnetic field is often preferred, especially in clinical applications. However, all objects that are placed in the magnetic field will disturb the field homogeneity and cause local magnetic field gradients. LÄS MER