Sökning: "polymer gel"

Visar resultat 11 - 15 av 119 avhandlingar innehållade orden polymer gel.

  1. 11. Radiotherapy Gel Dosimetry: Development and Application of Normoxic Polymer Gels

    Författare :Helen Gustafsson; Malmö Medicinsk strålningsfysik; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; Clinical physics; radiology; tomography; medical instrumentation; Klinisk fysiologi; tomografi; medicinsk instrumentering; Radiofarmaceutisk teknik; Radiopharmaceutical technology; proton; LET; FT Raman spectroscopy; MRI; normoxic gel; IMRT; 3D verification; polymer gel dosimetry; radiologi;

    Sammanfattning : In many radiotherapy applications, true three-dimensional dosimetry with good spatial resolution that can be achieved in a single measurement would be of great value. Polymer gel dosimetry fulfils many of the demands on such a system. In this study, methods to facilitate the implementation of gel dosimetry have been investigated. LÄS MER

  2. 12. Colloidal interactions and arrested dynamics of cellulose nanofibrils

    Författare :Malin Nordenström; Lars Wågberg; Torbjörn Pettersson; Lars Göran Ödberg; Andreas Fall; Wim Thielemans; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; NATURVETENSKAP; NATURAL SCIENCES; NATURVETENSKAP; NATURAL SCIENCES; NATURVETENSKAP; NATURAL SCIENCES; Cellulose nanofibrils; colloidal interactions; colloidal stability; arrested state; colloidal glass; colloidal gel; tracer diffusion; counterion; steric stabilization; redispersion; redispersion agent; Fiber- och polymervetenskap; Fibre and Polymer Science;

    Sammanfattning : Over the past decades, concerns for the environment have increased and efforts to achieve a sustainable society have intensified. One particular challenge is to replace fossil-based plastics with biodegradable materials produced from renewable resources. LÄS MER

  3. 13. Dynamics of Disordered Materials in Confined Geometries

    Författare :Christer Svanberg; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; polymer film; glass transition; confinement; polymer gel; dynamics; dielectric spectroscopy; gel electrolytes; relaxation; photon correlation; cooperativity;

    Sammanfattning : This thesis is concerned with effects of geometrical confinement on dynamics in disordered materials in the nanoscopic range. Of particular interest is the dynamics around the liquid to glass transition. Two systems have been investigated: thin polymer films and polymer gels. LÄS MER

  4. 14. Phase Phenomena in Polymer Networks : Empirical Studies on the Influence of Hydrophobicity, Charge Density and Crosslinks on Macroion-Induced Phase Transitions in Polyelectrolyte Gels

    Författare :Martin Andersson; Per Hansson; Lennart Piculell; Uppsala universitet; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; NATURVETENSKAP; NATURAL SCIENCES; Gel; microgel; microsphere; polystyrenesulfonate; polyacrylate; polyacrylicacid; DoTAB; DoTAC; CTAB; CTAC; network; polyelectrolyte; complex salt; self assembly; phase behaviour; hysteresis; thermodynamic; core-shell; lysozyme; cytochrome c; microscopy; micromanipulator; elastomer; elastic; protein; surfactant; phase behaviour; sorting; PHARMACY; FARMACI; Physical chemistry; Fysikalisk kemi;

    Sammanfattning : The thesis concerns polyelectrolyte gels in contact with oppositely charged proteins and surfactant micelles, and includes of four papers (I-IV). In paper I confocal Raman spectroscopy was introduced as a method to trace micelles and investigate the structure of gel-surfactant complexes, in phase separated gel spheres. LÄS MER

  5. 15. 3D Verification of Dynamic and Breathing Adapted Radiotherapy using Polymer Gel Dosimetry

    Författare :Sofie Ceberg; Malmö Medicinsk strålningsfysik; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; radiotherapy; 3D verification; polymer gel;

    Sammanfattning : Polymer gel dosimetry has been used since the 1990s, and several studies have shown that this detector system can be used for verification of static absorbed dose distributions in three dimensions (3D). Its unique properties, such as high resolution, normal tissue equivalence and independency of energy, field size and direction of the incident radiation, should also be advantageous for dosimetric verification of radiotherapy using today’s and tomorrow’s dynamic delivery techniques. LÄS MER