Sökning: "pin"

Visar resultat 16 - 20 av 184 avhandlingar innehållade ordet pin.

  1. 16. Silicon Carbide Technology for High- and Ultra-High-Voltage Bipolar Junction Transistors and PiN Diodes

    Författare :Arash Salemi; Mikael Östling; Carl-Mikael Zetterling; Anders Hallen; Nando Kaminski; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Informations- och kommunikationsteknik; Information and Communication Technology;

    Sammanfattning : Silicon carbide (SiC) is an attractive material for high-voltage and high-temperature electronic applications owing to the wide bandgap, high critical electric field, and high thermal conductivity. High- and ultra-high-voltage silicon carbide bipolar devices, such as bipolar junction transistors (BJTs) and PiN diodes, have the advantage of a low ON-resistance due to conductivity modulation compared to unipolar devices. LÄS MER

  2. 17. Wear characteristics of materials for artificial hip joints

    Författare :Mohammed Seyed Hoseini Nazari; RISE; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; HDPE; UHMWPE; Coating; Tribology; Pin-on-disc; Y-irradiation; Vitamin E; Wear; Implant; Artificial hip joint;

    Sammanfattning : Total hip prostheses have succeeded in significantly improving the quality of life of millions of patients worldwide. Ultra high molecular weight polyethylene (UHMWPE) has been widely and successfully used as a bearing material in orthopaedic prostheses since the 1960s. LÄS MER

  3. 18. Assessment of acetabular cup wear with computed tomography and influence of surface roughness on wear of materials for hip prostheses

    Författare :Anneli Jedenmalm; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Hip prostheses; Computed Tomography; Surface roughness; UHMWPE; Wear; Coating; γ-irradiation; pin-on-disc; hip simulator; Other materials science; Övrig teknisk materialvetenskap;

    Sammanfattning : Over one million hip prostheses are implanted in patients worldwide each year and the need is increasing as the patient group of younger and more active patients is increasing. Many parameters affect the longevity of the implant, where aseptic loosening caused by wear debris is the most common reason for revision. LÄS MER

  4. 19. Particle emissions from car brakes : The influence of contact conditions on the pad-to-rotor interface

    Författare :Mattia Alemani; Ulf Olofsson; Jens Wahlström; Anders Söderberg; Staffan Jacobson; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Car brakes emissions; transition temperature; working conditions; environmental design; pin-on-disc; Bilbromsutsläpp; övergångstemperatur; arbetsförhållanden; miljödesign; pinne-på-skiva; Machine Design; Maskinkonstruktion;

    Sammanfattning : Due to their adverse health effects emissions have been regulated for over three decades. Brake wear particulate matter is the most important non-exhaust source, however current knowledge is mainly limited to observational studies. LÄS MER

  5. 20. Computed Tomography of Acetabular Cup Wear and Effect of Surface Roughness on Wear and Oxidation of UHMWPE Hip Prostheses

    Författare :Anneli Jedenmalm; Ulf Gedde; André Stark; Karin Jacobson; Nicklas Axén; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Hip prostheses; Computed Tomography; Surface roughness; UHMWPE; Wear; Coating; Gamma-irradiation; pin-on-disc; hip simulator; Medical engineering; Medicinsk teknik;

    Sammanfattning : Aseptic loosening is the most common complication in total hip replacement (5- 10% at 10 years follow up). The magnitude of the problem is illustrated by the fact that about one million hip prostheses are implanted worldwide each year. LÄS MER