Sökning: "loosening"

Visar resultat 1 - 5 av 84 avhandlingar innehållade ordet loosening.

  1. 1. Aseptic Loosening of Orthopedic Implants : Osteoclastogenesis Regulation and Potential Therapeutics

    Författare :Mehdi Amirhosseini; Anna Fahlgren; Göran Andersson; Teun J. de Vries; Linköpings universitet; []
    Nyckelord :NATURVETENSKAP; NATURAL SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES;

    Sammanfattning : Aseptic loosening is the main cause of failure of orthopedic prostheses. With no pharmaceuticals to prevent or mitigate periprosthetic bone degradation, a surgery to replace the loose implant with a new one is the only choice to restore patients’ function. LÄS MER

  2. 2. Kinematics and fixation of total knee arthroplasties : a clinical, radiographic, scintimetric, and roentgen stereophotogrammetric evaluation

    Författare :Kjell G. Nilsson; Johan Kärrholm; Leif Ryd; Umeå universitet; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; Total knee arthroplasty; tibial component; kinematics; micromotion; loosening; scintimetry; roentgen stereophotogrammetric analysis;

    Sammanfattning : Aseptic loosening of the tibial component is an important cause of failure after total knee arthroplasty. Bone destruction often claimed to be caused by the cement makes the revision difficult. In order to treat younger patients, uncemented fixation has been introduced, but the etiology to loosening is multifactorial and only partly known. LÄS MER

  3. 3. Radiographic assessment of cup migration and wear after hip replacement

    Författare :Thomas Ilchmann; Lund Ortopedi; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; Surgery; measurement; assessment; loosening; migration; wear; cup; Hip; arthroplasty; orthopaedics; traumatology; Kirurgi; ortopedi; traumatologi;

    Sammanfattning : Methods are needed for accurate measurement of acetabular cup migration and wear after hip replacement. The EBRA (Ein Bild Röntgen Analyse) method was recently introduced as a computerized method for radiographic assessment of acetabular cup migration. LÄS MER

  4. 4. On late complications with HA coated hip arthroplasties

    Författare :Magne Røkkum; Göteborgs universitet; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; hip arthroplasty; hydroxyapatite; wear; osteolysis; loosening; clinical; radiological and histological examination;

    Sammanfattning : 100 hips in 86 patients were operated with a total hip arthroplasty entirely coated with a 155±35 µm thick HA coating, and included in a clinical and radiological follow-up study. The female/male ratio was 75/25, and the mean age was 56 years (32-73). Early clinical results were excellent, especially pain relief. No thigh pain was found. LÄS MER

  5. 5. On the aetiology of aseptic loosening in joint arthroplasties, and routes to improved cemented fixation

    Författare :Mikael Sundfeldt; Göteborgs universitet; []
    Nyckelord :MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; knee prosthesis; aseptic loosening; polyethylene particles; endotoxin; bone cement; sodium fluoride;

    Sammanfattning : Background: Aseptic loosening is the most common single cause for revisions in major joint arthroplasties worldwide. Different theories for aseptic loosening have been discussed during the last two decades. There is a need for improving fixation in both cemented and uncemented implants. LÄS MER