16. Development of Automated Algorithms for Epicardial Adipose Tissue Analysis in Computed Tomography and their Application in Population Based Research
Sammanfattning : The epicardial adipose tissue (EAT), which surrounds the heart and is separated from other tissues only by the thin layers of the pericardium, has enjoyed intense research for the past decades. Increased inflammatory activity in the EAT in coronary artery disease has, together with associated volumetric expansion of the EAT and changes in its radiodensity supported theories that the EAT might play a role in the pathogenesis of coronary atherosclerosis or mirror its progression better than traditional risk factors. LÄS MER
17. Computed Tomography of Acetabular Cup Wear and Effect of Surface Roughness on Wear and Oxidation of UHMWPE Hip Prostheses
Sammanfattning : Aseptic loosening is the most common complication in total hip replacement (5- 10% at 10 years follow up). The magnitude of the problem is illustrated by the fact that about one million hip prostheses are implanted worldwide each year. LÄS MER
18. Quantification and Maximization of Performance Measures for Photon Counting Spectral Computed Tomography
Sammanfattning : During my time as a PhD student at the Physics of Medical Imaging group at KTH, I have taken part in the work of developing a photon counting spectrally resolved silicon detector for clinical computed tomography. This work has largely motivated the direction of my research, and is the main reason for my focus on certain issues. LÄS MER
19. Assessment of acetabular cup wear with computed tomography and influence of surface roughness on wear of materials for hip prostheses
Sammanfattning : Over one million hip prostheses are implanted in patients worldwide each year and the need is increasing as the patient group of younger and more active patients is increasing. Many parameters affect the longevity of the implant, where aseptic loosening caused by wear debris is the most common reason for revision. LÄS MER
20. Characterization and Optimization of Silicon-strip Detectors for Mammography and Computed Tomography
Sammanfattning : The goal in medical x-ray imaging is to obtain the image quality requiredfor a given detection task, while ensuring that the patient dose is kept as lowas reasonably achievable. The two most common strategies for dose reductionare: optimizing incident x-ray beams and utilizing energy informationof transmitted beams with new detector techniques (spectral imaging). LÄS MER