Sökning: "Medical Equipment Engineering"

Visar resultat 1 - 5 av 60 avhandlingar innehållade orden Medical Equipment Engineering.

  1. 1. The Bone Conduction Implant (BCI) - Preclinical Studies, Technical Design and a Clinical Evaluation

    Författare :Hamidreza Taghavi; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; Bone conduction implant; Amplitude modulation; Bone anchored hearing aid; Radio frequency power amplifier and inductive link; Long-term implantation.; Low-power systems; Implanted transducer;

    Sammanfattning : The Bone Conduction Implant (BCI) system has been developed as an alternative to the percutaneous bone anchored hearing aid (BAHA) with the advantage that the skin is kept intact. The transducer is permanently implanted and attached to the skull via a flat surface contact to the temporal bone. LÄS MER

  2. 2. A Segmented Silicon Strip Detector for Photon-Counting Spectral Computed Tomography

    Författare :Cheng Xu; Hans Bornefalk; Mats Danielsson; Ami Altman; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; photon counting; spectral computed tomography; silicon strip detector; ASIC; energy resolution; cadmium telluride; charge sharing; Monte Carlo simulation; synchrotron;

    Sammanfattning : Spectral computed tomography with energy-resolving detectors has a potential to improve the detectability of images and correspondingly reduce the radiation dose to patients by extracting and properly using the energy information in the broad x-ray spectrum. A silicon photon-counting detector has been developed for spectral CT and it has successfully solved the problem of high photon flux in clinical CT applications by adopting the segmented detector structure and operating the detector in edge-on geometry. LÄS MER

  3. 3. Mid-infrared photonic devices for on-chip optical gas sensing

    Författare :Floria Ottonello Briano; Kristinn B. Gylfason; Delphine Marris-Morini; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; NATURVETENSKAP; NATURAL SCIENCES; NATURVETENSKAP; NATURAL SCIENCES; mid-infrared; mid-IR; photonics; silicon photonics; gas sensing; optical sensing; optical gas sensing; spectroscopy; absorption; dispersion; carbon dioxide; CO2; CO2 sensing; trace gas; ethanol sensing; alcohol sensing; waveguide; photonic waveguide; ring resonator; nanowire; nanoheater; emitter; thermal source; bolometer; microbolometer; thermal detector; high frequency; 3 omega method; plasmonic; platinum; Kanthal; silicon-on-insulator; micro-electro-mechanical systems MEMS ; microfabrication; microsystems; microtechnology; nanotechnology; Optik och fotonik; Optics and Photonics; Electrical Engineering; Elektro- och systemteknik;

    Sammanfattning : Gas detection is crucial in a wide range of fields and applications, such as safety and process control in the industry, atmospheric sciences, and breath diagnostics. Optical gas sensing offers some key advantages, compared to other sensing methods such as electrochemical and semiconductor sensing: high specificity, fast response, and minimal drift. LÄS MER

  4. 4. Hyperthermia-responsive liposomal systems

    Författare :Yujia Jing; Chalmers tekniska högskola; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; NATURVETENSKAP; NATURAL SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; MEDICIN OCH HÄLSOVETENSKAP; MEDICAL AND HEALTH SCIENCES; cationic lipid; asymmetry; phospholipase; liposomes; flip-flop; hyperthermia; phase transition; supported lipid membranes; drug delivery;

    Sammanfattning : Abstract Sophisticated liposomal systems are emerging at an increasing rate to meet the demands for multifunctional drug carriers in chemotherapies in combined with hyperthermia. For example, liposomal drug carriers for temperature-controlled drug release under hyperthermic conditions have recently been tested in clinical trials. LÄS MER

  5. 5. Wireless Multi-Sensor Feedback Systems for SportsPerformance Monitoring : Design and Development

    Författare :Dennis Sturm; Lars-Åke Brodin; Kjartan Halvorsen; Martin Eriksson; Kaj Lindecrantz; Richard Smith; KTH; []
    Nyckelord :TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; TEKNIK OCH TEKNOLOGIER; ENGINEERING AND TECHNOLOGY; kayak; paddle; mobile phone; sports performance; propulsive force; boat velocity; sampling frequency; wireless measurement; wireless sensor; Kayak XL System; sensor piconet; sensor platform; user-centred design;

    Sammanfattning : Wireless applications have become a common part of daily life. Whether it is mobile phones, the Wi-Fi router at home, the keycard which has replaced the car key, a radio frequency identification access system to a building or a Bluetooth headset for your computer or phone, the means of modern wireless data exchange is an omnipresent technology. LÄS MER